The gap you are showing is 3 8 that s about 1 8 to 3 16 above the accepted norm.
Gap frameless shower door.
They put a clear rubber gasket type thing on the edge which i don t care for but even with that i can stick a finger all the way through the gap.
If the door does not swing in both directions then swinging it out will allow water to drip off onto the floor.
It s important to keep in mind the limitations of the fabricator and the installer.
The seal on the bottom left side of the door drags hard on the curb but on the right side it does not.
This is the industry standard.
Invest in a shower door side seal to solve the leakage issue from the sides.
The gap should be 3 8 total or 3 16 at each side of the door or less is ideal.
Thanks for any input.
Gap spacing in frameless shower doors.
We ve had our bathroom remodeled and i have a question about the frameless shower door.
Hinge side gap is 5 at the top 25 in the middle and 25 at the bottom.
The shower enclosure was installed today and it looks great.
They also are easier to keep clean.
Frameless shower doors minimize the number of places water can collect and mold can grow in your shower.
It is 1 8 at the top and 3 8 at the bottom.
Well except for the large gap between the shower door and one side of the enclosure.
The standard tolerance for frameless shower glass is plus or minus 1 8.
With framed shower doors you run the risk of water build up underneath the door s seals allowing mold and mildew to form.
Gap spacing in frameless shower doors 09 february 2015.
If you find frameless shower door leaks at both the sides of the glass then you will have to seal the gap between the door and the adjacent glass wall.
I design frameless showers every day and install the complicated ones.
Solutions for fixing the leaks on either side of the frameless shower door.
The glass was custom measured but when the door was installed the gap between the door and the adjacent glass isn t uniform.
Unlike a framed shower unit the door in a frameless shower cannot be sealed shut and therefore small amounts of water can escape.
We ve had our bathroom remodeled and i have a question about the frameless shower door.
February 9 2015 showcase shower door santa cruz leave a comment go to comments.
The gap from glass to glass where the strike side of the door meets the fixed panel at the vertical gap is normally 3 16.
As the door is currently installed the strike side gap is 1 1 8 at the top 1 3 8 in the middle and 1 1 2 at the bottom.
The glass was custom measured but when the door was installed the gap between the door and the adjacent glass isn t uniform.